TeraTerm

B450 Plug-In Communicator Interface
Plug-In Not Connected

*** Status ***
Link Status: Error
Bus Status: Not Connected
Module Status: Trouble
Tamper: Disabled
Access Level: Full

*** Main Menu ***
1 = Status (Starts With Basic Status)
2 = Change Passcode
3 = Basic Configuration
4 = Advanced Configuration
5 = Reset To Factory Defaults
6 = Diagnostic Log
7 = Firmware Update
8 = Exit

Select Option? 3

*** Basic Configuration Menu ***
0 = Main Menu
1 = TCP/UDP Port Number: 7700
2 = AES Encryption: Disabled
3 = Module Enclosure Tamper: Enabled
4 = Panel Programming: Enabled
5 = Inbound SMS: Enabled
6 = Reporting Delay for Low Signal Strength (sec.): 1800
7 = GSM/GPRS Configuration
8 = Email Server Configuration

Select Option? 7

*** GSM/GPRS Configuration Menu ***
0 = Basic Configuration Menu
1 = Network Access Point Name (APN): wyless.apn
2 = Network Access Point User Name: 2014
3 = Network Access Point Password: *******
4 = SIM PIN: None
5 = Session Keep Alive Period (min): 0
6 = Inactivity Timeout (min): 0

Select Option? 1

Enter the Network Access Point Name (wyless.apn):

Enter the Network Access Point Name (wyless.apn): wyless.com.attz

Network Access Point Name (APN): attz.net

*** GSM/GPRS Configuration Menu ***
0 = Basic Configuration Menu
1 = Network Access Point Name (APN): wyless.com.attz
2 = Network Access Point User Name: 2014
3 = Network Access Point Password: *******
4 = SIM PIN: None
5 = Session Keep Alive Period (min): 0
6 = Inactivity Timeout (min): 0

Select Option? 0

*** Basic Configuration Menu ***
0 = Main Menu
1 = TCP/UDP Port Number: 7700
2 = AES Encryption: Disabled
3 = Module Enclosure Tamper: Enabled
4 = Panel Programming: Enabled
5 = Inbound SMS: Enabled
6 = Reporting Delay for Low Signal Strength (sec.): 1800
7 = GSM/GPRS Configuration
8 = Email Server Configuration

Select Option? 0

Settings have changed. Save now (Y or N)? Y

Changes saved.

B450 Plug-In Communicator Interface
Plug-In Not Connected

*** Status ***
Link Status: Error
Bus Status: Not Connected
Module Status: Trouble
Tamper: Disabled
Access Level: Full

*** Main Menu ***
1 = Status (Starts With Basic Status)
2 = Change Passcode
3 = Basic Configuration
4 = Advanced Configuration
5 = Reset To Factory Defaults
6 = Diagnostic Log
7 = Firmware Update
8 = Exit

Select Option? 8

Firmware version: 3.02.007
Build: Sep 2 2014 15:02:24

Enter Passcode:


Go back to the Tools page